Industry Standards and Regulations (Mandatory Compliance)

OSHA Standards (USA)

  • General industrial warehouse minimum illuminance: 20 lumens/sq.ft (200 Lux) (for aisles and non-precision work areas).

  • Precision operation areas: Recommended ≥ 50 lumens/sq.ft (500 Lux).

IESNA (Illuminating Engineering Society of North America) Standards

  • Storage areas: 100 - 300 Lux (10 - 30 lumens/sq.ft).

  • Sorting/packaging areas: 300 - 1000 Lux (30 - 100 lumens/sq.ft).

China GB 50034-2013 (Architectural Lighting Design Standard)

  • General warehouse: 100 - 200 Lux (10 - 20 lumens/sq.ft).

  • Large logistics warehouse: 200 - 300 Lux (20 - 30 lumens/sq.ft).

  • Precision product warehouse: 300 - 500 Positives (30 - 50 lumens/sq.ft).

Safety and Compliance Supplements

Emergency Lighting

  • All warehouses must have emergency lighting with illuminance ≥ 10 Lux (1 lumen/sq.ft), with a minimum power supply duration of ≥ 90 minutes (complying with fire safety standards).

Glare Control

  • Forklift traffic zones and manual operation areas must avoid direct light into workers’ eyes. Use diffuse lampshades or anti-glare grilles (UGR ≤ 25).

Illuminance Uniformity

  • Work area uniformity (minimum illuminance/average illuminance) ≥ 0.7 to avoid visual fatigue due to uneven lighting.

 

Find the right light for your space.

Explore GGJIA lighting, compare your options, and get help with your next project.

JOIN THE CONVERSATION

Leave a comment

Your email address will not be published. All fields are required.

Comments are reviewed before publication.

READER DISCUSSION

Discussion

No comments yet. Be the first to share your thoughts.